Camlock Types A–F (Plus DC & DP): How to Pick the Right Fitting for Your Pump

Rental Pump Parts guide to Camlock types A–F, showing male adapters, female couplers, dust caps and plugs.
Camlock Types A–F Explained: Chart & Pairing Guide | Rental Pump Parts

Mixing up camlock types is one of the most common reasons a dewatering job stalls at the first connection. This guide explains camlock types A–F so you can order the right fitting the first time, whether you run one trash pump or a full rental fleet.

Quick answer: In camlock types A–F, types A, E and F are male adapters, while B, C and D are female couplers. The letter describes the tail end (thread or hose shank), and male always mate with females. DC caps a male end and DP plugs a female end. Match the opposite gender to your equipment port, confirm size and thread, then choose material and gasket.

Ready to buy camlock fittings? You can shop camlock types A–F plus DC and DP in every size and material, and pick the right fitting for your pump right now.

Camlock Types A–F, DC and DP Explained

How a Camlock Works: The One Rule Behind Every Pairing

Every camlock pairing follows one rule: a male adapter slides into a female coupler of the same size, so the male vs female camlock decision always comes first. Pushing the coupler’s two cam arms flat makes their lugs catch the groove on the adapter and draw it tight against a gasket, creating the seal. No tools are needed, which is why camlocks dominate quick-connect hose work.

Camlock Types A–F at a Glance

Use this camlock fittings chart to match each type to its connection.

Jump to: Type A camlock | Type B camlock | Type C camlock | Type D camlock | Type E camlock | Type F camlock | DC dust cap | DP dust plug

Type Camlock end Tail end Threads or clamps onto Typical job
Type A camlock Male adapter Female NPT thread Male-threaded pipe or pump port Male camlock end on a male-threaded port
Type B camlock Female coupler Male NPT thread Female-threaded pipe or pump port Female camlock end on a female-threaded port
Type C camlock Female coupler Hose shank Hose, secured with clamps Hose end that mates with a male adapter
Type D camlock Female coupler Female NPT thread Male-threaded pipe or pump port Female camlock end on a male-threaded port
Type E camlock Male adapter Hose shank Hose, secured with clamps Hose end that mates with a female coupler
Type F camlock Male adapter Male NPT thread Female-threaded pipe or pump port Male camlock end on a female-threaded port
DC (dust cap) Female cap Closed Covers male adapters (A, E, F) Keeps grit out of open male ends
DP (dust plug) Male plug Closed Plugs female couplers (B, C, D) Seals open female ends and protects the gasket

DC covers the male side; DP plugs the female side. That is the whole camlock dust cap vs dust plug distinction: a dust cap (female) goes over a male adapter, and a dust plug (male) goes into a female coupler. Fit one on every open end to keep grit out of grooves and gaskets.

Which Camlock Types Connect? Pairing Matrix

Treat this grid as the second half of your camlock fittings chart. A ✔ means the two ends mate (same size assumed), and a ✘ means both ends share a gender. Male × male and female × female pairings need a gender-changing adapter, such as a double-male or double-female camlock. DC and DP seal open ends and are not meant to join each other (–).

A B C D E F DC DP
A (male) ✘ ✔ ✔ ✔ ✘ ✘ ✔ ✘
B (female) ✔ ✘ ✘ ✘ ✔ ✔ ✘ ✔
C (female) ✔ ✘ ✘ ✘ ✔ ✔ ✘ ✔
D (female) ✔ ✘ ✘ ✘ ✔ ✔ ✘ ✔
E (male) ✘ ✔ ✔ ✔ ✘ ✘ ✔ ✘
F (male) ✘ ✔ ✔ ✔ ✘ ✘ ✔ ✘
DC (female) ✔ ✘ ✘ ✘ ✔ ✔ ✘ –
DP (male) ✘ ✔ ✔ ✔ ✘ ✘ – ✘

How to Choose the Right Camlock Type

The Port-First, Four-Step Method

Start at the equipment, not the hose.

  1. Identify the equipment end. Is the pump port male-threaded, female-threaded or already a camlock?
  2. Choose the opposite gender. A male-threaded port takes a female-threaded tail (Type A or D); a female-threaded port takes a male-threaded tail (Type F or B). This is the male vs female camlock call that prevents most wrong orders.
  3. Confirm size and thread. Match nominal size and thread standard (NPT or BSP), then size the hose-side C or E to the hose inside diameter.
  4. Match material and gasket to the fluid, temperature and pressure.

NPT vs BSP Camlock: The Thread Trap

NPT is the standard on US-made pumps, but imported equipment often uses BSP, and the two do not interchange. NPT threads are tapered with 60° flanks and seal as they wedge together with sealant. BSP threads have 55° flanks and come parallel (BSPP), which seals at a washer or O-ring, or tapered (BSPT). Mixed threads may start, then weep or strip. To confirm your port, check the pump manual or data plate, test with a thread pitch gauge and measure the outside diameter with calipers. Settle the NPT vs BSP camlock question before you order.

Material, Gasket and Pressure

Aluminum camlock fittings cover most water and fuel work, while stainless steel camlock fittings handle corrosive and abrasive duty. Choose the body for the environment, then the gasket for the fluid chemistry.

Option Part Best for Watch out for
Aluminum Body Water, dewatering, many petroleum products; light and economical Strong acids and alkalis; galvanic corrosion against dissimilar metals
Stainless steel (304/316) Body Corrosive and abrasive duty; long wear life Heavier and costlier
Brass Body Water, fuels, non-sparking environments Ammonia-bearing chemicals; lead content on potable-water lines
Polypropylene (poly) Body Chemical transfer, light handling, low cost UV exposure and heat reduce strength
NBR (Buna-N) Gasket Water, oils, fuels Strong acids, ozone, ketones
EPDM Gasket Water, many acids and alkalis Petroleum oils and fuels
Viton (FKM) Gasket Fuels, oils, many chemicals Ketones, hot water, steam
PTFE Gasket Aggressive chemicals Firm material that needs clean, undamaged seating faces

Pressure ratings step down as size increases and vary by manufacturer, so work from the manufacturer’s spec sheet rather than generic ranges. Poly fittings must also be derated as fluid temperature rises. For interchangeability, look for dimensions that follow A-A-59326 (US) or EN 14420-7 (Europe).

Once you’ve matched the body and gasket, browse aluminum, stainless steel, brass and poly camlock fittings, including types A–F, DC and DP, matched to your pump port and fluid.

Real Dewatering Setups: Putting the Types to Work

Worked Example: Trash Pump Suction and Discharge

Consider a 3-inch trash pump, a classic case for camlock fittings for dewatering pumps. Apply the same logic to suction and discharge: the port’s thread gender decides the pump-side fitting, and the hose side takes the opposite camlock gender.

Pump port Pump-side fitting Hose-side fitting
Male-threaded Type A (male camlock end) Type C (female coupler)
Male-threaded Type D (female camlock end) Type E (male adapter)
Female-threaded Type F (male camlock end) Type C (female coupler)
Female-threaded Type B (female camlock end) Type E (male adapter)

Clamp each hose to its shank, and confirm the port’s thread standard (NPT vs BSP) before ordering.

Suction vs Discharge: Protect Prime and Flow

Suction and discharge fail in different ways. A leaking discharge joint is easy to spot, but a worn gasket on the suction side pulls in air, breaks prime and cuts flow with little to see. Treat every suction joint as critical: inspect gaskets before each job, lock every cam arm and keep the suction chain as short as possible. Avoid stacking reducers, because each one adds friction loss and another place for air to enter; use a single reducing fitting where you must change size. Run your hose length and size through our Pump Calculator to estimate friction loss before you deploy.

Camlock vs Bauer Coupling vs Flanged: Where Camlock Stops

Camlock vs Bauer coupling comes down to size, speed and pressure. Camlocks are the fastest option on smaller hose, Bauer couplings suit larger-diameter pipe, and flanged joints handle the highest pressures but take the longest to assemble.

Connection Typical size range Connect speed Pressure Cost
Camlock Roughly ½ to 6 in. Seconds, no tools Low to medium; drops as size grows Low
Bauer coupling Larger pipe, often 4 in. and up Fast, lever-style Medium Medium
Flanged Wide range, including very large Slowest: bolts and gaskets Highest Highest (parts plus labor)

These are typical figures only; confirm against the manufacturer’s spec sheet. Browse our Bauer coupling collection and flanged fittings collection for larger systems.

What to Stock: A Camlock Kit per Pump Size

A standard camlock kit for dewatering pumps keeps crews working when a fitting fails mid-job. For each pump size, stock:

  • Pump-port adapters: one per port (Type A, D, F or B), matched to port gender and thread.
  • Hose-end fittings: Type C and Type E for every hose end.
  • DC and DP: one for every open end. The camlock dust cap vs dust plug rule is simple: caps on male ends, plugs on female ends.
  • Spare gaskets in a material that suits your fluid.
  • Reducers for your most common size changes, so you never need to stack them.

Pick one fleet-wide gender convention, such as male adapters on every pump port and a female coupler on the pump-facing end of each hose, and label every hose and port with tape or tags so crews never have to guess. For help building a kit, see how Rental Pump Parts supports rental fleets with camlock types A–F, DC and DP and helps you match the right fitting to each pump.

Care, Safety and Troubleshooting

Camlock fittings are simple, but a worn gasket or an unlocked cam arm can cost you a prime, a pump or an injury. Build a quick inspection into every setup and teardown, and relieve pressure before you disconnect any coupler.

Inspect, Lock and Fix Common Failures

Check gaskets, lugs and arms before every deployment, then use this table to diagnose problems fast.

Symptom Likely cause Fix
Weeping at the joint Worn, flattened or nicked gasket; debris in the seat Clean the seat and replace the gasket with the correct material
Leak at the thread NPT vs BSP camlock mismatch or too little thread sealant Confirm the thread standard, then reseal with a compatible sealant
Stuck or stiff cam arms Grit, dried residue, corrosion or bent arms Flush and clean, apply a gasket-compatible lubricant, replace bent arms
Arms open under vibration No safety pin or clip; worn lugs Fit safety pins or clips; replace worn fittings
Corrosion at threads Galvanic reaction between mixed metals, such as stainless into aluminum Match metals or isolate them with a suitable sealant; inspect often
Cracked, chalky poly UV exposure and age Store out of sunlight; replace cracked fittings
Lost prime, no visible leak Air entering at a suction gasket or thread Inspect every suction joint; replace gaskets

Safety: Fit a safety pin or clip on every cam arm on pressurized lines, keep arms folded flat, and drain and depressurize before disconnecting. Retire any fitting with bent arms, worn lugs or a damaged seat.

Retire any damaged fitting, then restock camlock types A–F, DC and DP for your dewatering jobs and choose the right replacement fitting for your pump from our collection.

Frequently Asked Questions

Camlocks come in eight standard types. Male adapters are A, E and F; female couplers are B, C and D. The letter shows what’s on the tail end: thread or hose shank. DC dust caps cover male adapters, while DP dust plugs seal female couplers.

No single type wins, but Type C and Type E are the everyday workhorses. Most hose assemblies run a Type E on one end and a Type C on the other. Add Type A or F at pump ports, depending on thread gender.

Start with the gasket: replace it if cracked, worn or swollen, and match its material to the fluid, since EPDM, Viton, Buna-N and PTFE differ in heat, chemical and oil resistance. Clear debris from the groove, confirm both halves are the same size, and close both cam arms fully. If the leak is at the threaded tail, check NPT-versus-BSP compatibility and reseal.

Sources most often cite Type C and Type E as the everyday hose-end pair, with A and F used at equipment ports. Some industry tables favor B, D and F for chemical transfer and A, E and F for fuel, though material and gasket matter more than the letter.

Type F is a male camlock adapter with male threads. It’s known for screwing into female-threaded pump inlets, outlets, valves and tank ports, creating a fixed male connection point. The Type F can stay installed while a female Type C hose coupler connects and disconnects.

Sources point to material, not the type letter. PerfectQRC recommends stainless steel camlocks with Viton seals for chemicals; CamlockDepot reserves stainless for corrosive or food-grade duty, using polypropylene for light-duty chemicals. Always verify gasket and body compatibility with a chemical-resistance chart.

The Right Camlock Is the One You Never Think About

A camlock is a small part doing a big job. Choose the right type by matching gender, thread, size, material and gasket, and the connection disappears into the work: secure, leak-free, whether it joins one pump or a whole fleet. Pumps move the water, but fittings decide whether it goes where you need it. The best connection is the one you never think about again.

When you’re ready to equip your crew, explore Rental Pump Parts for dewatering pump supplies, including camlock types A–F with DC and DP, and learn how to pick the right fitting.

Rental Pump Parts

Address: 504 Western Drive, Mobile, 36607 AL, United States